copper-enamel-banner

Enamel/Magnet and Fiber Covered Round & Rectangular Wire

 

Magnet wire is used to convert energy. It is wound in the form of coil around the core present in electric-electronic appliances such as heavy electric, automobiles and home appliance industry etc.

Range
Copper wire: 0.15mm-4.50mm
Copper Strip: Width: 3.00mm to 25.00mm & Thickness: 0.50mm to 4.00mm

 

PHYSICAL PROPERTIES

Product Chemical Viscosity by at 23°c (MPa.s) solid Content (% by wt.) Recommended for wire size (mm dia) Class of wire °c Distinctive properties or wire enamel/enamelled wire Relevant specification for wires
Terebec 227-35 Modified polyester 110-135 34-36 0.2-5.0 130 Excellent Flexibility & adherence IS 13730-34 IEC 60317-34
Terebec 256-40 Modified polyester 600-800 39-41 0.05-2.0 155 Low viscosity excellent heat shock IS 13730-3 IEC 60317-3
Terebec TR543-38 THEIC Polyesterimide 750-850 37-39 0.05-1.6 180 High tan & bending point and cut through property UL approved. IS 13730-3 IEC 60317-8
IsomeIt 1566 M 30 Polyurethane 20-32 29-30 0.05-0.8 155 High processing speeds good solder ability high tan IS 13730-20/ IEC 60317-20
1380-29 Polyurethane 95-145 28-30 0.1-0.4 180 High processing speeds good solder ability high tan IEC 60317-51
1380-25 ml Polyurethane 45-75 24-26 0.02-0.5 180 High processing speeds good solder ability high tan IEC 60317-51
Terebec TR 543-38 Allotherm 602L.35 THEIC Polyester imide+Polymideimide

750-850

650-800

37-39

34-36

0.315-1.6 200 Excellent hermetic & burnout resistance high speed wind ability IS 13730-13 IEC 60317-13
Terebec SL225-40 A A|1013 BV/35 THEIC Polyester imide+Polymideimide

440-540

700-1500

39-41

34-36

0.315-3.0 200 Excellent hermetic Resistance improved mechanical properties IS 13730-13 IEC 60317-13
Terebec FN Polymideimide 85-100 32-34 2.0-5.0 mm dia & upto 60 sq mm rect 155 good adherence for rectangular wires IS 13730-3/IEC 60317-3 IS 13730-16/ IEC 60317-16
Terebec Mt533- 36PA THEIC Polymideimide 80-90 35-37 1.6-5.0 mm dia & upto 60 sq mm rect 180 Excellent adhesion heat shock & thermal resistance IS 13730-8/IEC 60317-8 IS 13730-28/ IEC 60317-28


ELECTRICAL PROPERTIES

Property Copper Wires/Strips/Flats
Resistivity at 20° C < 0.01724 ohms mm2/m
Conductivity (IACS) 100%


BREAK DOWN VOLTAGE (BDV)

  Minimum BDV For Grade 1 (Fine Covering)
Minimum BDV For Grade 2 (Med. Covering) Minimum BDV For Grade 3 (Thick Covering)
Size 1mm-2.5mm 2.700kv 5.000kv 7.600kv
Size Over 2.5mm 1.300kv 2.500kv 3.800kv
Copper Strips 1.000kv 2.000kv 2.500kv

  • Magnet WiresEnamel/Magnet Wires
  • Magnet StripsEnamel/Magnet Strips
  • Fiber Covered StripsFiber covered strips